HSF-100 Orthogonal standard series

  • fluxgate sensor 8

    General Description:

    The orthogonal standard series contains a 3-axis fluxgate sensor with orthogonality  ≤±0.2°. The user can input the reliable measurement result into processing software to modify the algorithm as needed. This product is ideal for measurement of a 3-component, magnetic-filed dynamic platform. 

    Features

    • Wide band

    • Low noise

    • High sensitivity

    • Excellent linearity

    • Low power consumption

    • Reliable orthogonality

    Applications

    • Geomagnetic survey

    • Environmental magnetic field measurement

    • Underwater magnetic detection

    • Target detection and location

    3 versions (divided according to frequency domain noise):

    • Normal version(11~20pTrms/Hz1/2@1Hz)

    • Standard version(7~10pTrms/Hz1/2@1Hz)

    • Low noise version(≤6pTrms/Hz1/2@1Hz)

    • The parameters have been tested strictly by the authorized organization. 


  • 3 versions (divided according to frequency domain noise):

    • Normal version(11~20pTrms/Hz1/2@1Hz)

    • Standard version(7~10pTrms/Hz1/2@1Hz)

    • Low noise version(≤6pTrms/Hz1/2@1Hz)

    • The parameters have been tested strictly by the authorized organization. 

  • Parameters      

    • Axis:1/3

    • Orthogonal degree:≤±0.2°

    • Linearity:≤0.01%

    Noise

    • (1)Low noise version:≤6pTrms/Hz1/2@1Hz

    • (2)Standard version:7~20pTrms/Hz1/2@1Hz

    • (3)Normal version:>20pTrms/Hz1/2@1Hz (or only time frequency noise is provided)

    (Note: This is the noise parameter of the sensor with the measuring range less than 100µT)

    Band Width 

    • (1)DC~100Hz

    • (2)DC~500Hz

    • (3)DC~1KHz

    • (4)DC~1.5KHz

    Sensitivity

    Measuring range

    ±70µT

    ±100µT

    ±250µT

    ±500µT

    ±1mT

    ±5mT

    ±10V

    output

    142.86mV/µT

    100mV/µT

    40mV/µT

    20mV/µT

    10mV/µT

    2mV/µT

    ±4.5V

    output

    64.28mV/µT

    45mV/µT

    18mV/µT

    9mV/µT

    4.5mV/µT

    *

    ±2.5V

    output

    35.71mV/µT

    25mV/µT

    10mV/µT

    5mV/µT

    2.5mV/µT

    *

    Electrical Parameters

    • High voltage power supply: ±12V~±15VDC,±10V analog voltage output, power consumption = 0.45W;

    • Medium voltage power supply:±5VDC,±4.5V analog voltage output, power   

      Consumption = 0.14W;

    • Low voltage power supply:±3.6V, ±2.5V analog voltage output, power consumption = 35mW;

    • Note: The minimum power consumption is 30mW.

    Housing Type


    • Standard housing:30x30x120mm, 7-core waterproof joint(IP68), weight = 220g, default of external cable length = 0.5m; 


    • Non magnetic interface housing: 30x33x126mm, 9-core non magnetic connector, weight = 190g;

    • Cube housing: 60x60x60mm, 7-core waterproof joint(IP68), weight = 335g, default of external cable length = 0.5m; 

    • Parted housing: Probe dimension is 28x28x37mm, body dimensions are 30x30x120mm, 9-core nonmagnetic connector weight = 200g.

      These housing methods are suitable for testing in environments such as a laboratory, the wild, aviation and shallow water. In standard housing, the sensor body can operate a ta depth of 300 meters underwater. There is also a model with a large measuring range up to ±5mT.

  • Enterprise Tenet

    Provide customers with high quality products, solutions and services to
    achieve the common success of enterprises and employees.