Designed for low-field magnetic measurement in geomagnetic research, geological survey, and laboratory applications.
Typical Applications
• Geomagnetic field measurement and monitoring
• Geological survey and mineral exploration
• UAV and airborne magnetic survey
• Laboratory magnetic experiments and calibration
Is this sensor suitable for your application?
• Designed for low-field magnetic measurement within the Earth magnetic field range
• Suitable for long-term stable measurement and field deployment
• Can be integrated into UAV and other moving platforms with proper magnetic isolation
• Not intended for high-frequency dynamic magnetic field measurement
Key Technical Highlights
• Low noise performance, critical for detecting weak geomagnetic variations
• ±100 μT measurement range, matching typical Earth magnetic field levels
• Good linearity and orthogonality, suitable for three-component magnetic analysis
• Low power consumption, supporting long-duration field surveys
Field-Proven Performance
• Verified through long-term comparative testing with international fluxgate sensors
• Comparable signal quality to optical pump magnetometers in aeromagnetic surveys
• Mean Time Between Failures (MTBF) ≥ 100,000 hours
Performance Parameters
Index Name | Parameters |
Axis | 1/3 |
Orthogonality | ≤±0.2° |
Linearity | ≤0.01%FS |
Noise | Low noise version | Standard Version | Normal Version |
≤6pTrms/Hz1/2@1Hz (Measuring range ±70uT) | ≤10pTrms/Hz1/2@1Hz | ≤20pTrms/Hz1/2@1Hz |
Bandwidth | DC~100Hz | DC~1KHz | DC~3KHz |
Temperature Range | -20℃~60℃ | -40℃~80℃ |
Note | This is the noise within the range of ±100uT. With the increase of the sensor range, the noise will increase appropriately |
Range/uT, Output Voltage/V, Sensitivity mV/uT
Range | ±70µT | ±100µT | ±250µT | ±500µT | ±1mT | ±2mT |
±10V Output | 142.86mV/µT | 100mV/µT | 40mV/µT | 20mV/µT | 10mV/µT | 5mV/µT |
±4.5V Output | 64.28mV/µT | 45mV/µT | 18mV/µT | 9mV/µT | 4.5mV/µT | 2.25mV/µT |
±2.5V Output | 35.71mV/µT | 25mV/µT | 10mV/µT | 5mV/µT | 2.5mV/µT | 1.25mV/µT |
Electrical parameters
Supply Voltage | Working Current | Output Voltage |
±12V~±15VDC | 35mA | ±10V |
±3.6V~±5VDC | 10mA | ±2.5V |
±5V~±6VDC | 28mA | ±4.5V |
Product Packaging Form

Standard Packaging: 30*30*120mm, 7-core waterproof connector (protection grade IP68), weight about 220g, external wiring length is 0.5m by default

Non magnetic interface package: 30 * 33 * 126mm, imported 9-pin non-magnetic connector, weighing about 190g
Note: The frequency domain noise in the table refers specifically to the fluxgate magnetic sensor with sensitivity greater than 100mV/μT