hotline:

0086-29-88385072

Fluxgate Magnetic Sensor

Home>Magnetic Field Measurement>Fluxgate Magnetic Sensor

HSF-200 Standard Series Fluxgate Magnetic Sensor

Product Overview
HSF-200 Standard Series fluxgate sensor is series sensor with low noise down to 6pT and high accuracy developed by Xi'an Huashun company. It is suitable for the application field where the orthogonality index of the sensor is not strict. It is also very suitable for three-component magnetic field measurement based on non moving platform. Compared with the orthogonal standard series HSF-100, it has higher cost performance. With high resolution and light weight, 3 axis fluxgate magnetic field sensor was widely used for magnetic anomaly measurement as detector and magnetic survey measurement equipment. With strong R&D team and OEM capability, SMAGALL is committed to develop high sensitivity sensors to contribute to geophysical surveys in the geomagnetic field industry. After 23 years of development, SMAGALL fluxgate sensors are comparable to advanced foreign products and have been well received by users who are looking for mag690 sensors FG sensors, bartington instruments

Product Features
Wide band, Low Noise, High Sensitivity, Good linearity, Low Power consumption

Application
Geomagnetic measurement, environment magnetic field measurement, etc..

Performance Parameters

Index Name

Parameters

Axis

1/3

Mechanical   orthogonality

≤±0.2°

Linearity

≤0.01%FS

Noise

Low noise version

Standard Version

Normal Version

≤6pT rms/Hz1/2@1Hz

≤10pT rms/Hz1/2@1Hz

≤20pT rms/Hz1/2@1Hz

Bandwidth

DC~100Hz

DC~1KHz

DC~3KHz

Temperature Range

-20℃~60℃

-40℃~80℃

Note

This is the noise within the range of ±100uT. With the increase of the sensor range,   the noise will increase appropriately

Range/uT, Output Voltage/V, Sensitivity mV/uT

Range

±70uT

±100uT

±250uT

±500uT

±1mT

±2mT

Output Voltage±10V

142.86mV/uT

100mV/uT

40mV/uT

20mV/uT

10mV/uT

5mV/uT

Output Voltage±4.5V

64.28mV/uT

45mV/uT

18mV/uT

9mV/uT

4.5mV/uT

2.25mV/uT

Output Voltage±2.5V

35.71mV/uT

25mV/uT

10mV/uT

5mV/uT

2.5mV/uT

1.25mV/uT

Electrical parameters

Supply Voltage

Working Current

Output Voltage

 ±12V~±15VDC

35mA

±10V

 ±3.6V~±5VDC

10mA

±2.5V

±5VDC~±6VDC

28mA

±4.5V

Product Packaging Form

Standard Packaging: 30*30*110mm, 7-core waterproof connector (protection grade IP68), weight about 210g, external wiring length is 0.5m by default

Note: The frequency domain noise in the table refers specifically to the fluxgate magnetic sensor with sensitivity greater than 100mV/μT


* Your Name
* Email
* Company
* Country
Phone
* Message
Verification Code