Fluxgate magnetometer sensor measures magnetic field value by nonlinear relationship between magnetic induction intensity and the measured magnetic field intensity of high permeability magnetic core under saturation excitation of alternating magnetic field. Fluxgate magnetic sensor can measure static magnetic field and alternating magnetic field with high precision, and can measure three perpendicular magnetic field components at most at the same time. Fluxgate magnetometer sensor is especially suitable for vector measurement of weak magnetic field and high resolution measurement of magnetic field, such as geomagnetic measurement, geological exploration, material nondestructive testing and space magnetic field measurement with the characteristics of high resolution, good linearity, wide frequency response and low noise. This magnetic sensor adopts waterproof design, and can be used in underwater and outdoor environment.
HSF-200 Standard Series fluxgate sensor is series sensor with low noise down to 6pT and high accuracy developed by Xi'an Huashun company. It is suitable for the application field where the orthogonality index of the sensor is not strict. It is also very suitable for three-component magnetic field measurement based on non moving platform. Compared with the orthogonal standard series HSF-100, it has higher cost performance. With high resolution and light weight, 3 axis fluxgate magnetic field sensor was widely used for magnetic anomaly measurement as detector and magnetic survey measurement equipment. With strong R&D team and OEM capability, SMAGALL is committed to develop high sensitivity sensors to contribute to geophysical surveys in the geomagnetic field industry. After 23 years of development, SMAGALL fluxgate sensors are comparable to advanced foreign products and have been well received by users who are looking for mag690 sensors FG sensors, bartington instruments
Product Features
Wide band, Low Noise, High Sensitivity, Good linearity, Low Power consumption
Application
Geomagnetic measurement, environment magnetic field measurement, etc..
Performance Parameters
Index Name | Parameters |
Axis | 1/3 |
Mechanical orthogonality | ≤±0.2° |
Linearity | ≤0.01%FS |
Noise | Low noise version | Standard Version | Normal Version |
≤6pT rms/Hz1/2@1Hz | ≤10pT rms/Hz1/2@1Hz | ≤20pT rms/Hz1/2@1Hz |
Bandwidth | DC~100Hz | DC~1KHz | DC~3KHz |
Temperature Range | -20℃~60℃ | -40℃~80℃ |
Note | This is the noise within the range of ±100uT. With the increase of the sensor range, the noise will increase appropriately |
Range/uT, Output Voltage/V, Sensitivity mV/uT
Range | ±70uT | ±100uT | ±250uT | ±500uT | ±1mT | ±2mT |
Output Voltage±10V | 142.86mV/uT | 100mV/uT | 40mV/uT | 20mV/uT | 10mV/uT | 5mV/uT |
Output Voltage±4.5V | 64.28mV/uT | 45mV/uT | 18mV/uT | 9mV/uT | 4.5mV/uT | 2.25mV/uT |
Output Voltage±2.5V | 35.71mV/uT | 25mV/uT | 10mV/uT | 5mV/uT | 2.5mV/uT | 1.25mV/uT |
Electrical parameters
Supply Voltage | Working Current | Output Voltage |
±12V~±15VDC | 35mA | ±10V |
±3.6V~±5VDC | 10mA | ±2.5V |
±5VDC~±6VDC | 28mA | ±4.5V |
Product Packaging Form
Standard Packaging: 30*30*110mm, 7-core waterproof connector (protection grade IP68), weight about 210g, external wiring length is 0.5m by default
Note: The frequency domain noise in the table refers specifically to the fluxgate magnetic sensor with sensitivity greater than 100mV/μT